Protect critical research and prevent biological hazards with precision-engineered environmental enclosures. Farclean designs, manufactures, and deploys high-containment laboratory cleanroom systems tailored for Biosafety Level (BSL-1 to BSL-4) facilities, analytical testing labs, and advanced R&D centers worldwide.
Certified Compliance Standards: ISO 14644-1 | CDC/NIH Biosafety Guidelines | BSL-1 to BSL-4 Standards | EU GMP Grade A-D | WHO Laboratory Biosafety Manual
Modern biological and chemical R&D laboratories demand rigorous contamination control, precise air pressure differential cascades, and resilient containment barriers. Farclean offers integrated enclosure systems that safeguard both researchers and scientific integrity.
BIM/CAD design optimized for directional airflow, dedicated Personnel/Material Airlocks (PAL/MAL), and strict negative or positive pressure zoning.
In-house manufacturing of chemical-resistant Rockwool/Honeycomb modular sandwich panels, airtight flush doors, and seamlessly coved joints to prevent bio-burden accumulation.
Custom HVAC architectures featuring tight temperature/humidity control, high air exchange rates (ACPH), and safe-change (BIBO) bag-in/bag-out filter housings for lethal pathogens.
Complete qualification packages, room tightness testing, HEPA filter integrity test reports, and pressure differential balancing logs to guarantee fast facility commissioning.
| Containment Level | Airflow & Pressure Control Logic | Target Facility Application |
|---|---|---|
| Standard R&D Cleanroom (ISO 5–8) | Positive pressure cascade (+10 to +15 Pa) preventing outdoor particle ingress. | Analytical testing labs, precision instrument calibration, formulation R&D. |
| BSL-2 / BSL-3 Bio-Containment | Negative pressure differential (-15 to -30 Pa) with 100% single-pass exhaust air. | Virology research, infectious disease labs, diagnostic testing, cell culture suites. |
| BSL-4 Maximum Containment | Deep negative pressure, gas-tight sealed enclosures, double HEPA BIBO exhaust. | Exotic pathogen research, biodefense facilities, high-consequence viral laboratories. |
Challenge: A regional biomedical institute required a fast-track build for a BSL-3 virology testing lab paired with an ISO Class 6 cell culture suite within 60 days.
Solution: Farclean supplied factory-prefabricated modular steel wall panels, inflatable gasket airtight doors, BIBO exhaust filter plenums, and VHP-resistant ceiling grids.
Result: The laboratory passed third-party pressure decay tests, containment validation, and microbial safety audits on the first pass, entering operational status 10 days ahead of deadline.
Our modular panels feature completely smooth, non-porous surface coatings joined by tongue-and-groove profiles sealed with continuous medical-grade silicone. This provides a gas-tight seal essential for maintaining stable negative pressure gradients and resisting aggressive VHP gaseous decontamination cycles.
Farclean integrates specialized Bag-In/Bag-Out (BIBO) exhaust filtration systems. This allows technical personnel to safely replace contaminated HEPA/ULPA filters without exposing the technicians or external environment to biological agents.
Yes. As a turnkey system manufacturer, we provide complete Design Qualification (DQ), Installation Qualification (IQ), and Operational Qualification (OQ) protocols along with factory material certificates, duct leak test logs, and air balancing reports.